kidde novec1230 125lb cylinder round shoulder 45-100125-001-rnd 06-100125-001-rnd 45-100121-001-rnd

Kidde Novec-1230 125Lb (56Kg, 50.6 Ltr) round shoulder Fire Suppression Cylinder, with agent (45-100125-001-rnd)

kidde novec1230 200lb cylinder round shoulder full tank 45-100200-001-rnd 06-100200-001-rnd 45-100201-001-rnd

Kidde Novec-1230 200Lb (90Kg, 81 Ltr) round shoulder Fire Suppression Cylinder, with agent (45-100200-001-rnd)

Kidde Novec-1230 125Lb (56Kg, 50.6 Ltr) square shoulder Fire Suppression Cylinder, with agent (45-100125-001)

Kidde Novec-1230 125Lb (56Kg, 50.6Ltr) square shoulder Cylinders, which can be filled with between 28.6Kg and 56.7Kg of Gas Suppression Agent. (45-100125-001 06-100125-001 45-100121-001)
SKU
45-100125-001
Kidde Novec-1230 125Lb (56Kg, 50.6 Ltr) square shoulder Fire Suppression Cylinder, with agent (45-100125-001) is available to buy in increments of 1

FSP Can Supply new, Refill, Hydrostatic test and service Kidde Novec-1230 125Lb (56Kg, 50.6Ltr) square shoulder Cylinders, which can be filled with between 28.6Kg and 56.7Kg of Gas Suppression Agent. (45-100125-001 06-100125-001 45-100121-001) The cylinders are equipped with a 1.5-inch pressure differential valve and pressure gauge. The safety burst disc is also located on the cylinder head.

Contact us if you need these cylinders with the optional liquid level indicator or optional low-pressure switch assembly.

Novec-1230 is required to be kept under pressure otherwise it vaporises. Dry Nitrogen is used to provide the constant pressure required to keep the agent in liquid form in the tank.

Kidde Novec-1230 125Lb (56Kg) Cylinder Specifications

  • Height = 810mm
  • Valve Size = 1.5inch
  • Min Fill = 28.6Kg
  • Max Fill = 56.7Kg
  • Gross Weight = 101.2Kg
kidde novec 1230 cylinder size

Kidde Novec-1230 125Lb (56Kg) Cylinder Data Sheet

Spec Sheet Icon kidde novec-1230 k-45-2010 Cylinder Valve Assem Vertical Mnt Only 10-7-14

FSP Cylinder Exchange Service

Our Exchange Fire Suppression Cylinders kits have been decanted, dried, inspected, refurbished, hydrostatically tested and refilled.

Our exchange Cylinders have all been tested within 12 months or less, so you get years more service without having to re-test your pressure vessels.

Contact FSP for Cylinder Exchange quote.

Cylinder Transport Service

FSP can organise fast reliable Fire Cylinder Transportation and delivery service Australia-wide.

We have our own fleet of specialist trucks and delivery drivers who can deliver cylinders to a premesis out of hours to avoid interuption to critical assets.

Contact FSP with your customised Transportation needs.