Simplex <p>Wired Media Card RS485 (for older leagcy 4100+ Version 3 or earlier network cards) (4100-0142K)</p>

Simplex

Wired Media Card RS485 (for older leagcy 4100+ Version 3 or earlier network cards) (4100-0142K)

Simplex/VESDA High Level Interface (HLI) Panel Mount I/F (4100-0154K)

Simplex/VESDA High Level Interface (HLI) Panel Mount I/F (4100-0154K)

Simplex Wired media card suit 4100U - ES Media Card (4100-6056)

$462.84
Wired media card suit 4100U - ES Media Card
SKU
4100-6056

Wired (RS485) Network Media Card to suit 4100U - 4100ES

Mounts on 4100-6078 (Simplex Modular Network Interface for Master Controller) or 4100-6061 (Simplex Modular Network Interface for Redundant Master Controller) Network Interfaces

Features

Simplex® Fire Alarm Network communications are available for wired or fiber optic connections:

  • Wired communications are available on Network interface modules; available with either wired connections only, or as a modular design allowing selection of either wired or fiber optic media modules.
  • Fiber optic communications are available with fiber media modules on the Network interface modules or when using the higher performance multiple signal fiber optic modems
  • Fiber optic links are point-to-point continuous (unswitched) connections between Fire Alarm Network nodes.
  • LED status indicators assist with system setup and servicing.

Multiple communication signal modems use laser optical transmitters to provide:

  • Increased transmission distances compared to copper wiring (over 20 miles (32 km) may be possible with low-loss single-mode fiber).
  • Designs are optimized for fiber type; models are selected for single mode fiber, or multi-mode fiber.
  • Multiple signal modems are two slot modules and are available with separate enclosures if required for smaller Network node control panels.
  • Class B or Class X communications using wired media or fiber optics; selectable separately to match media requirements.

Wired media module details:

  • Provides isolated earth detection.
  • Compatible with Simplex isolated loop and overvoltage protectors.
  • Electrical characteristics are similar to RS-485.
  • Network signal fiber optic media module:

    • Fiber optic links provide immunity to electrical transients, short circuits, and ground conditions.
    • LED based fiber optic media module uses two multi-mode fibers to communicate; has type ST connectors, compatible with 62.5/125 or 50/125 fiber.
    • Bi-Directional Couplers are available to allow use of single fiber cable (for Network communications).

    Multiple communications fiber optic modules provide:

    • Laser based half-duplex communications over single fiber connections.
    • Available for single mode, or multi-mode fiber.
    • Refer to information summary on pages 2 and 3 and to data sheet S4100-0049 for additional feature description

      Physical Bridge Modules connect multiple Network loops and provide Star topology connections:

      • Physical Bridge Modules connect to Network communications using wired or fiber optic media and interconnect using modem media modules (refer to data sheet S4100-0057 for details)
      • TCP/IP Physical Bridge Modules are similar but provide LAN (Local Area Network) compatible interconnections (refer to data sheet S4100-0029 for details)

      Possible Markings on Board: 565-413

      Spares Group: 4120 Networking modules