Kidde 80L 300bar IG-55 Cylinder with C60 Valve with Exchange, refill and testing Argonite (01-1524-5900-C60)

Kidde 80L 300bar IG-55 Cylinder Argonite with C60 Valve Exchange, refill and testing (01-1524-5900-C60 6-01-1524-5900-K)
SKU
01-1524-5900-C60

FSP Can Supply Kidde 80L 300bar IG-55 Cylinder Argonite with C60 Valve Exchange, refill and testing (01-1524-5900-C60 6-01-1524-5900-K) steel, seamless gaseous fire suppression Container, filled with Inert Gas and Controlled Flow Technology is designed to reduce peak mass flow by ~60%.

Argonite (IG-55) is a clean-agent Inert Gas Fire Suppression agent that leaves no residue on discharge and is environmentally friendly.

IG-55 (Argonite) is a Mixture of 50% nitrogen and 50% Argon.

Argonite systems consist of one or more high pressure steel cylinders connected via a common manifold. The gas is distributed in the protected room via a distribution pipe system with nozzles. The inerting and extinguishing properties of Argonite act quickly to eliminate the fire. System actuation is manual or automatic by a fire detection system.

The use of the 300 bar Argonite system can reduce the number of steel cylinders by 30%. This results in more space for alternative uses or a reduction in building costs. Fewer cylinders also mean lower costs for transport, installation and maintenance as well as a smaller cost for replacing the cylinders after a discharge. The extinguishing system is brought into operating conditions quickly and cost effectively.

Kidde 80L 300bar IG-55 Cylinder Exchange, refill and testing with C60 Valve Technical Specifications and Information

  • 60% reduction in peak mass flow.
  • 60% reduction in enclosure pressure relief venting panel and area of aperture in the enclosed wall and therefore real savings on vent installation costs.
  • Vent size can be accurately determined at the quotation stage of a project instead of relying on hydraulic flow calculations.
  • 60% reduction in noise (vibration during discharge) for reduced effect on sensitive electromechanical equipment.
  • 60 bar outlet pressure allows the maximum possible flow and therefore the use of smaller-diameter pipes in the distribution network.
  • Elimination of high–pressure manifolds and restrictors for single zone systems without reduction in discharge nozzle pressure (60 bar).
  • If more than one area in a building needs to be protected, there is no need to install several systems. A single bank of cylinders can be stored remotely from the risks with directional valves to divert the gas to where it is needed.
  • Up to 60 cylinders may be actuated from a single high performance release unit.
  • Easy to install with minimal risk and reduced installation time.
Kidde Argonite IG55 C60 Valve Mass Flow over Time Graph

Kidde 80L 300bar IG-55 Cylinder with C60 Valve Exchange, refill and testing Data Sheet

Spec Sheet Icon Kidde Argonite C60 Brochure ENG

Kidde Argonite Material Safety Data Sheet 2012

Applications

ARGONITE® C60 can be used to suppress fire in a diverse and challenging range of applications.

  • Data Processing
  • Data Centres, Computer Suites, Telecom Centres, Tape Storage Libraries, UPS Rooms, Financial Centres and Banks
  • Cleanrooms
  • Electronic equipment manufacturing, Medical and Laboratory Equipment, Biotechnology, Pharmaceutical and Medical Facilities, Operation Rooms, Universities and Colleges
  • Communications
  • Internet Service Providers, Switch Rooms, Control Centres, Cell Sites, Railway Signalling Centres, Air Traffic Management Centres, Military Installations
  • Heritage preservation
  • Art Galleries, Museums, Libraries, Classic Car Garages, Cultural Centres, Archive Stores
  • Power generation
  • Generators, Gas Turbines, Substations, Control Rooms
  • Oil & Gas
  • Offshore Oil and Gas Installations, Pipeline Pumping Stations, Petrochemical Plants

FSP Cylinder Exchange Service

Our Exchange Fire Suppression Cylinders kits have been decanted, dried, inspected, refurbished, hydrostatically tested and refilled.

Our exchange Cylinders have all been tested within 12 months or less, so you get years more service without having to re-test your pressure vessels.

Contact FSP for Cylinder Exchange quote.